1
“...We demonstrate intracavity optical pumping of J-aggregate microcavity exciton polaritons. The use...”
Get full text
Get full text
Get full text
Get full text
Format: Article
2
by Nadeau, Phillip, Paidimarri, Arun, Mercier, Patrick Philip, Chandrakasan, Anantha P.
Published 2015
“... total of 180pJ/b from a 0.7V supply while achieving a BER=10-3 sensitivity of -67dBm at a 1Mb/s data...”Published 2015
Get full text
Get full text
Get full text
Get full text
Format: Article
3
by Osedach, Timothy Paul, Iacchetti, Antonio, Lunt, Richard R., Andrew, Trisha Lionel, Brown, Patrick Richard, Akselrod, Gleb Markovitch, Bulovic, Vladimir
Published 2014
“...We demonstrate a near-infrared photodetector that consists of a thin film of the J-aggregating...”Published 2014
Get full text
Get full text
Get full text
Get full text
Format: Article
4
by Demirbas, Umit, Hong, Kyung-Han, Fujimoto, James G., Sennaroglu, Alphan, Kaertner, Franz X.
Published 2012
“...We report a low-cost, cavity dumped Cr:LiSAF laser, generating 135-fs pulses at 825 nm, with 105 nJ...”Published 2012
Get full text
Get full text
Get full text
Get full text
Format: Article
5
by Hong, Kyung-Han, Lai, Chien-Jen, Siqueira, Jonathas, Moses, Jeffrey, Smrz, Martin, Zapata, Luis E., Krogen, Peter Ra, Kaertner, Franz X., Lai, Chein-Jen
Published 2015
“...We report on a multi-mJ 2.1-μm OPCPA system operating at a 1-kHz repetition rate, pumped by a...”Published 2015
Get full text
Get full text
Get full text
Get full text
Get full text
Format: Article
6
7
by Paidimarri, Arun, Mercier, Patrick Philip, Chandrakasan, Anantha P., Nadeau, Phillip
Published 2015
“...-shaping. Peak PA efficiency is 44.4% and peak TX efficiency is 33%. The entire TX consumes 440pJ/bit at 1...”Published 2015
Get full text
Get full text
Get full text
Get full text
Format: Article
8
“... pulses with energies of 9.9 nJ and peak powers of ~101 kW, corresponding to 95 mW of average power at a...”
Get full text
Get full text
Get full text
Get full text
Get full text
Get full text
Format: Article
9
“...-cycle intervals from 4.8 μs to 1 day. The round-trip save-restore energy is 3.4 pJ per NVDFF. Also...”
Get full text
Get full text
Get full text
Get full text
Format: Article
10
11
“.... The measured energy consumption is 0.077~0.168 nJ per bit per iteration and 0.39~0.85 nJ per bit....”
Get full text
Get full text
Get full text
Get full text
Format: Article
12
“..., our 10mm SRLR-based low-swing datapath achieves 6.83Gb/s/µm bandwidth density with 40.4fJ/bit/mm...”
Get full text
Get full text
Get full text
Get full text
Get full text
Get full text
Format: Article
13
14
15
16
17
18
19
20